SLIM-DUAL

Dual-tech PIR+MW motion detector

SLIM-DUAL detects motion in the protected area. The device can be installed on the BRACKET D adjustable wall-and-ceiling mounting holder.

  • certificate of compliance with the EN 50131 requirements for Grade 2
  • motion detection using two sensors: a passive infrared (PIR) sensor and a microwave (MW) sensor
  • adjustable detection sensitivity of both sensors
  • digital motion detection algorithm
  • digital temperature compensation
  • digital filter of signals received by the microwave sensor to ensure immunity to false alarms caused by the power network and discharge lamps
  • wide-angle lens, designed specifically for SLIM LINE detectors
  • option to replace the wide-angle lens with a curtain (CT-CL2) or long-range (LR-CL2) one
  • built-in end-of-line resistors (2EOL: 2 x 1,1 kΩ)
  • LED indicator
  • selectable color of LED indicator for alarm signaling (4 colors available)
  • LED indicator remote enable/disable
  • supervision of motion detection and supply voltage circuit
  • tamper protection against opening of enclosure
5 years warranty
EN-50131 GRADE 2 - certificate
SLIM-DUAL
The actual appearance of the products may differ from the presented images. Product descriptions are provided in the web service for information purposes only.

Documentation

quick installer guide
updated: 2020-06-05
443 KB
general information manual
updated: 2020-02-04
603 KB
mounting template
updated: 2022-03-25
233 KB

Certificates

EN-50131 GRADE 2 - certificate
updated: 2023-02-14
1.81 MB
EU declaration of conformity
updated: 2023-10-27
772 KB

Technical Data

Supply voltage
12 V DC
Detected target velocity
0,3...3 m/s
Operating temperature range
-10°C...+55°C
Recommended mounting height
2,4 m
Standby mode current consumption
10 mA
Max. current consumption
25 mA
Weight
101 g
Maximum humidity
93±3%
Dimensions
62 x 137 x 42 mm
Environmental class according to EN50130-5
II
Alarm signaling time
2 s
Complied with standards
EN 50131-1, EN 50131-2-4, EN 50130-4, EN 50130-5
Microwave frequency
24,125 GHz
Security grade according to EN50131-2-4
Grade 2
EOL resistors
2 x 1,1 kΩ
Warm-up period
30 s
Detection area
15 m x 20 m, 90° (montaż na 2,4 m)
Alarm outputs (NC relay, resistive load)
40 mA / 24 V DC
Tamper outputs (NC)
100 mA / 30 V DC
Relay contact resistance (alarm output)
26 Ω
Permissible installation height
up to 4 m

Information materials

1catalogue

3leaflet - installer

4technical data