Korzystasz z poprzedniej wersji strony – zapraszamy na nową odsłonę satel.pl!
You're browsing the previous version of this website. Go to satel.pl/en/ and see how we've changed!

Brand new INT-TSH2 and INT-TSG2
touchscreen keypads

Powerful processor, completely new interface,
swipe gestures support.
Meet the new level
of safety and building automation control.

Register for a free online course now

Choose a topic and learn with SATEL technical specialists.
For professional installers only.

CONFX hardware configurator

New version now available!

  • Even more useful functions
  • Easier and faster designing
  • New appearance

SMART BUILDING solutions

KNX modules

now available in SATEL's offer!

Find out more

SATEL on YouTube and Vimeo

Over 30 films and animations about us and our products

- subscribe to our channels and stay up to date!

 

CA-64 ADR

Addressable bus expansion module

Meet the successor CA-64 ADR!

 

INT-ADR

Addressable zone expansion module

CHECK

 

This module is designed to connect addressable detectors to the INTEGRA control panel. It facilitates the process of routing cables, in particular in extensive installations. The addressable detectors bus is independent from the control panel expansion modules bus, which makes it possible to create hybrid systems, i.e. combining addressable and directly connected elements. A back-up power supply built in the module ensures additional power to supply alarm system elements.

  • dedicated independent bus for addressable detectors
  • support for up to 48 addressable zones
  • switching mode power supply
discontinued
CA-64 ADR
The actual appearance of the products may differ from the presented images. Product descriptions are provided in the web service for information purposes only.

Documentation

general information manual
updated: 2012-01-20
185 KB

Technical Data

Power supply rating
2,2 A
Board dimensions
140 x 68 mm
Weight
125 g
Current consumption from battery - maximum
45 mA
Current consumption from battery - standby
45 mA
Recommended transformer type
TR40VA (40 VA / 18 V AC)
Output voltage range
9,5…13,8 V DC
Battery failure voltage threshold (±10%)
11 V
Battery cut-off voltage (±10%)
9,5 V
Battery charging current (switch-over)
350 / 700 mA
Supply voltage (±10%)
18 V AC, 50-60 Hz
Current consumption from the transformer: standby
115 mA
Current consumption from the transformer: maximum
115 mA
POW output current-carrying capacity
1,5 A
Number of handled addressable detectors
48

Information materials

1catalogue

4technical data

5product data sheet

 © 1990-2021 SATEL sp. z o.o.
legal | privacy policy | Feedback | about site

The Satel.pl website uses cookies to enable Users' to take advantage of Satel.pl features as well as for statistical purposes. Unless you block cookies, you grant your consent for their use and storage in device memory. You must remember that you are able to manage cookies by means of your browser settings. Lack of adjustment of these settings means your consent for the Satel.pl website to use the cookies. See our Privacy Policy for more information.

Zamknij